Top Suppliers Aluminum Coating For Corrosion Resistance - Rack Mounted Load Bank for data center, UPS – Wepower

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Bear "Customer first, Quality first" in mind, we work closely with our customers and provide them with efficient and professional services for Charge Discharge Test, Resistors Connected To Ground, Dynamic Braking Resistors Max Temperature, We sincerely welcome domestic and foreign merchants who calls, letters asking, or to plants to negotiate, we will offer you quality products and the most enthusiastic service,We look forward to your visit and your cooperation.
Top Suppliers Aluminum Coating For Corrosion Resistance - Rack Mounted Load Bank for data center, UPS – Wepower Detail:

█ Description:

The most effective approach to power and thermal load testing during commissioning that we have found is to utilize rack-mounted load banks (Figure 2). These are resistive heating element load bank units that mount in typical 19” server racks, plug into dual-circuit rack PDUs (power distribution units), and can be dialed-in to the expected load of the particular rack.  In this manner, the full load rack configuration can be simulated, as well as some partial theoretical/planned initial buildout. The fact that the loads can be configured to match expected loads, and at specific locations, can have a number of benefits to more representative testing. For example, hot aisle hot spots can be better detected, resulting from either airflow variations within the hot aisle or, perhaps, based on variations in performance by in-row cooling hardware. Further, N+1 testing of cooling equipment can be accurately simulated. If, for example, a data center is designed to to have 10 in-row cooling (IRC) units, but only requires 9 operational to meet heat rejection loads (i.e. 9 + 1 = 10), during design load testing, a single IRC can be failed and the hot aisle can be evaluated to determine if unacceptable hot aisle temps result near the failed IRC unit. Performing this kind of testing with floor load banks would be inconclusive at best.

Friendly Notice: we are willing to provide customized products for our customers with their logo.

Using Application: Data Center, Generator, UPS power supply, Inverter, project debugging, Laboratory, etc.

█ Parameters:

Rack Mounted Load Bank table sheet

TWLB-AC220V/6KW

Rated Voltage AC220V(±10%)single phase
Rated Power 6KW
Frequency 50Hz/60Hz
Power step 100W、200W、200W、500W、1KW、2KW、2KW
Control way Manual circuit breaker control
Display Voltage, current LED display
Power fact PF1.0
Accuracy ≤±5%
Display accuracy 0.5
Control power suppluy AC220V/50HZ
Level of protection IP20
Cooling way Forced air, forward wind, backward wind
Color Depending on customers
Dimension W460*D600*H270mm
Weight 30KG
Environment parameters
Working temperature -10℃~+55℃
Relative humidity ≤95%RH
Altitude ≤2500
Pressure 86~106kPa

 

Rack Mounted Load Bank table sheet

TWLB-DC650V/4KW

Rated Voltage

DC650V

Rated Power

4KW

Power step

100W,200W,200W,500W,1KW,2KW

Control way

Manual circuit breaker control

Display

Voltage, current LED display

Accuracy

≤±5%

Display accuracy

0.5级  0.5 degree.

Control power supply

AC220V/50HZ

Level of protection

IP20

Cooling way

Forced air, forward wind, backward wind

Color

Depending on customers

Dimension

W460*D600*H270mm

Weight

30KG

Working temperature

-10℃~+55℃

Relative humidity

≤95%RH

Altitude

≤2500

Pressure

86~106kPa

Optional function

PC control or HMI control

Remarks

For customizing products

Product detail pictures:

Top Suppliers Aluminum Coating For Corrosion Resistance - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures

Top Suppliers Aluminum Coating For Corrosion Resistance - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures

Top Suppliers Aluminum Coating For Corrosion Resistance - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures

Top Suppliers Aluminum Coating For Corrosion Resistance - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures

Top Suppliers Aluminum Coating For Corrosion Resistance - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures

Top Suppliers Aluminum Coating For Corrosion Resistance - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures


Related Product Guide:

Our target should be to consolidate and improve the high-quality and repair of current goods, in the meantime regularly produce new solutions to meet unique customers' needs for Top Suppliers Aluminum Coating For Corrosion Resistance - Rack Mounted Load Bank for data center, UPS – Wepower , The product will supply to all over the world, such as: Oslo, Cape Town, Milan, Our products are widely recognized and trusted by users and can meet continuously changing economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
  • As an international trading company, we have numerous partners, but about your company, I just want to say, you are really good, wide range, good quality, reasonable prices, warm and thoughtful service, advanced technology and equipment and workers have professional training, feedback and product update is timely, in short, this is a very pleasant cooperation, and we look forward to the next cooperation!
    5 Stars By Adela from Plymouth - 2017.08.28 16:02
    Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
    5 Stars By Elizabeth from Malta - 2018.12.28 15:18