Renewable Design for Load Bank Electrical - Crowbar/Chopper Resistor – Wepower

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

As a way to finest meet up with client's wants, all of our operations are strictly performed in line with our motto "High Quality, Aggressive Price, Fast Service" for H Bridge Braking Resistor, Grounding Resistor, Wire Wound Resistance Materials, The team of our company with the use of cutting-edge technologies delivers impeccable quality products supremely adored and appreciated by our customers worldwide.
Renewable Design for Load Bank Electrical - Crowbar/Chopper Resistor – Wepower Detail:

█ Application

Crowbar resistor is mainly used in low voltage ride through technology of wind power inverter. It is used at the rotor side of wind turbine generator to bypass the rotor side converter. In case of low voltage disturbance in the power grid, the DC bus voltage and rotor current shall be prevented from being too high. It mainly works in fault state to damp stator flux linkage. Crowbar resistors can dissipate huge amounts of energy instantaneously.

It is mainly used in the frequency conversion / converter system of doubly fed variable speed constant frequency generator units to improve the low voltage ride through capability of generator units, which is limited by the power grid
Large current impact caused by voltage drop protects excitation converter and limits rotor winding over voltage.

█ Feature:

The resistance material is imported alloy steel, which can absorb large energy impact in a short time, and can meet different power requirements.

█ structures:

Mica sandwich structure, traditional metal carrier grid structure and block carrier structure:
1. mica sandwich structure, with small volume, low cost and large heat capacity, is suitable for absorbing large energy in a short time and for single impact at long intervals (once a week).
2. with the traditional metal grid structure, the product has relatively moderate volume, relatively moderate cost and good heat dissipation performance. It is suitable for multiple impacts in a short time (once every 30 minutes). It can be used in crowbar resistor, chopper resistor and braking resistor circuits.
3. block carrier structure, the product has strong impact resistance and good heat dissipation performance. High structural strength and moderate price. Suitable for short-time multiple impact. It can be applied to crowbar resistor, chopper resistor, braking resistor and other circuits.

█ Life Time of Crowbar Resistor

200J 1 times/second  
220KJ 1 times/30mins 35000 times(20 years of life)
640KJ 1 times/week 1000 times(20 years of life)
1360KJ 1 times/month 260 times(20 years of life)
Take 1.5MW windmill generator as an example, environment temperature ≤ 60℃

█ Resistor Material Comparison

 Material

(g/mm3)

(Ω·mm2/m)

J/(g·K)

W/(m·K)

ppm/℃

SUS304

7.9

0.72

0.5

13.2

≤1400

SUS316

7.93

0.78

0.45

13.23

≤900

SUS310S

7.98

0.88

0.46

13.2

≤600

Cr20Ni80

8.4

1.09

0.441

16

≤100

█ Selection Table

Energy

Resistance

Time

Dimension(mm)

(L)mm

(W)mm

(H)mm

50KJ

3R

30mS

420

160

95

200KJ

2R

3.8S

285

178

150

500KJ

3.3R

3.8S

670

150

150

1.0MJ

0.36R

0.1S

395

190

153

1.5MJ

0.45R

3S

520

292

100

2.0MJ

0.4R

30mS

868

175

130

2.0MJ

0.5R

30mS

943

195

135

2.2MJ

0.7R

1S

446

240

153

2.5MJ

0.95R

3S

597

400

200

3.0MJ

0.7R

1S

432

240

153

Note: For other technical parameters & requirements, please contact with our company’s business man.


Product detail pictures:

Renewable Design for Load Bank Electrical - Crowbar/Chopper Resistor – Wepower detail pictures

Renewable Design for Load Bank Electrical - Crowbar/Chopper Resistor – Wepower detail pictures

Renewable Design for Load Bank Electrical - Crowbar/Chopper Resistor – Wepower detail pictures


Related Product Guide:

While using the "Client-Oriented" organization philosophy, a rigorous top quality command process, highly developed production devices and a potent R&D workforce, we normally provide high quality products, outstanding solutions and aggressive charges for Renewable Design for Load Bank Electrical - Crowbar/Chopper Resistor – Wepower , The product will supply to all over the world, such as: Zambia, Riyadh, panama, Our company follows laws and international practice. We promise to be responsible for friends, customers and all partners. We would like to establish a long-term relationship and friendship with every customer from all over the world on the basis of mutual benefits. We warmly welcome all old and new customers to visit our company to negotiate business.
  • The customer service staff's answer is very meticulous, the most important is that the product quality is very good, and packaged carefully, shipped quickly!
    5 Stars By Honorio from Leicester - 2017.04.08 14:55
    Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!
    5 Stars By Susan from Philippines - 2017.06.22 12:49