Factory Outlets Chemical Resistance Chart For Aluminum - Neutral Grounding Resistor, NGR EGR – Wepower

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We aim to find out quality disfigurement from the production and supply the best service to domestic and overseas customers wholeheartedly for Putting A Resistor To Ground, Floating Ground Resistor, Oil Cooled Braking Resistors, We put genuine and health as the primary responsibility. We have now a expert international trade crew which graduated from America. We are your next small business partner.
Factory Outlets Chemical Resistance Chart For Aluminum - Neutral Grounding Resistor, NGR EGR – Wepower Detail:

█ Product Features

1. Voltage range:0.33 ~110KV

2. Rated Current: 1~5000A

3. Resistance Range:0.1Ω∽1500Ω

4. Working time: 5s,10s,30s,60s,10mins,working continuous

5. Ingress Protection:IP20~IP55

6. Installation:Indoor、Outdoor;

7. Auxiliary parts: disconnecting switch, circuit breaker, CT, PT etc.

8. Resistor temperature rise:

1)Rated time :10s, maximum temperature rise≤760K;

2)Rated time : 10s<t<10mins, maximum temperature rise ≤610K;

3)Working continuous, maximum temperature rise ≤385K;

█ Wire Diagram

The electrical connection mode between neutral point three-phase AC power grid and earth, called grounding mode for neutral point. Neutral point grounding resistor principle diagram as follows:

image1

Neutral point of transformer, the grounding resistor has two ways:

On the secondary side the transformer is a star connection method, the neutral point grounding resistor straight. (see Figure.1)

On the secondary side the transformer is a triangle connection method, the neutral point grounding transformer grounding through grounding transformer. (see Figure. 2)

█ Production Selection Table

6.3KV series neutral grounding resistor selection table, as following:

Type

Neutral Voltage

Resistance

 Fault

Current

Rated

Time

Protection Class

Enclosure

Line Voltage

Phase Voltage

Length

Width

High

KV

KV

[Ω]

[A]

[s]

IP

[mm]

[mm]

[mm]

TNGR

6.3

3.64

72.8

50

10

IP2X

800

1000

1180

TNGR

6.3

3.64

36.4

100

10

IP2X

800

1000

1180

TNGR

6.3

3.64

18.2

200

10

IP2X

800

1000

1180

TNGR

6.3

3.64

14.6

250

10

IP2X

800

1000

1180

TNGR

6.3

3.64

12.1

300

10

IP2X

800

1000

1180

TNGR

6.3

3.64

9.1

400

10

IP2X

1000

1000

1180

TNGR

6.3

3.64

7.3

500

10

IP2X

1000

1000

1180

TNGR

6.3

3.64

6.1

600

10

IP2X

1000

1000

1180

TNGR

6.3

3.64

4.6

800

10

IP2X

1000

1000

1180

TNGR

6.3

3.64

3.6

1000

10

IP2X

1000

1000

1180

TNGR

6.3

3.64

3.0

1200

10

IP2X

1000

1000

1180

TNGR

6.3

3.64

2.6

1400

10

IP2X

1000

1000

1180

TNGR

6.3

3.64

2.3

1600

10

IP2X

1000

1000

1180

10.5KV series neutral grounding resistor selection table,as following:

Type

Neutral Voltage

Resistance Value

 Fault

Current

Rated

Time

Protection

Enclosure

Line Voltage

Phase Voltage

Length

Width

High

KV

KV

[Ω]

[A]

[s]

IP

[mm]

[mm]

[mm]

TNGR

10.5

6.06

121.2

50

10

IP2X

800

1000

1480

TNGR

10.5

6.06

60.6

100

10

IP2X

800

1000

1480

TNGR

10.5

6.06

30.3

200

10

IP2X

800

1000

1480

TNGR

10.5

6.06

24.3

250

10

IP2X

800

1000

1480

TNGR

10.5

6.06

20.2

300

10

IP2X

800

1000

1480

TNGR

10.5

6.06

15.2

400

10

IP2X

1000

1000

1480

TNGR

10.5

6.06

12.2

500

10

IP2X

1000

1000

1480

TNGR

10.5

6.06

10.1

600

10

IP2X

1000

1000

1480

TNGR

10.5

6.06

7.6

800

10

IP2X

1200

1000

1480

TNGR

10.5

6.06

6.1

1000

10

IP2X

1200

1000

1480

TNGR

10.5

6.06

5.1

1200

10

IP2X

1200

1000

1480

TNGR

10.5

6.06

4.3

1400

10

IP2X

1200

1000

1480

TNGR

10.5

6.06

3.8

1600

10

IP2X

1200

1000

1880

TNGR

10.5

6.06

3.4

1800

10

IP2X

1200

1000

1880

20KV series neutral grounding resistor selection table,as following:

Type

Neutral Voltage

Resistance Value

 Fault

 Current

Rated

Time

Protection

Enclosure

Line Voltage

Phase Voltage

Length

Width

High

KV

KV

[Ω]

[A]

[s]

IP

[mm]

[mm]

[mm]

TNGR

20

11.55

231

50

10

IP2X

1300

2300

2300

TNGR

20

11.55

115.5

100

10

IP2X

1300

2300

2300

TNGR

20

11.55

57.7

200

10

IP2X

1300

2500

2300

TNGR

20

11.55

46.2

250

10

IP2X

1300

2700

2300

TNGR

20

11.55

38.5

300

10

IP2X

1300

2700

2300

TNGR

20

11.55

28.9

400

10

IP2X

1300

2500

2300

TNGR

20

11.55

23.1

500

10

IP2X

1300

2500

2300

TNGR

20

11.55

19.3

600

10

IP2X

1300

2700

2300

TNGR

20

11.55

14.4

800

10

IP2X

2100

2500

2000

TNGR

20

11.55

11.6

1000

10

IP2X

2100

2500

2000

TNGR

20

11.55

9.6

1200

10

IP2X

2100

2500

2000

TNGR

20

11.55

8.3

1400

10

IP2X

2100

2500

2000

TNGR

20

11.55

7.2

1600

10

IP2X

2100

2700

2000

TNGR

20

11.55

6.4

1800

10

IP2X

2100

2700

2000

TNGR

20

11.55

5.8

2000

10

IP2X

2100

2700

2000

35KV series neutral grounding resistor selection table,as following:

Type

Neutral Voltage

Resistance Value

 Fault

 Current

Rated

Time

Protection

Enclosure

Line Voltage

Phase Voltage

Length

Width

High

KV

KV

[Ω]

[A]

[s]

IP

[mm]

[mm]

[mm]

TNGR

35

20.2

404.6

50

10

IP2X

1600

2600

2524

TNGR

35

20.2

202.3

100

10

IP2X

1600

2600

2524

TNGR

35

20.2

101.2

200

10

IP2X

1600

2800

2524

TNGR

35

20.2

80.9

250

10

IP2X

1600

3000

2524

TNGR

35

20.2

67.4

300

10

IP2X

1600

3000

2524

TNGR

35

20.2

50.6

400

10

IP2X

1600

2800

2524

TNGR

35

20.2

40.5

500

10

IP2X

1600

2800

2524

TNGR

35

20.2

33.7

600

10

IP2X

1600

3000

2524

TNGR

35

20.2

25.3

800

10

IP2X

2400

2800

2144

TNGR

35

20.2

20.2

1000

10

IP2X

2400

2800

2144

TNGR

35

20.2

16.9

1200

10

IP2X

2400

2800

2144

TNGR

35

20.2

14.5

1400

10

IP2X

2400

2800

2144

TNGR

35

20.2

12.6

1600

10

IP2X

2400

3000

2144

TNGR

35

20.2

11.2

1800

10

IP2X

2400

3000

2144

TNGR

35

20.2

10.1

2000

10

IP2X

2400

3000

2524

Remark: For other technical parameters & requirements, please contact with our company’s business man.

Stainless steel resistors ,CT is optional(if other equipment like grounding transformer, isolating switch, vacuum contactor and the rated time >10S, the enclosure dimensions will be adjusted )

█ Main Executive Standard

• Specification for neutral-earth resistance in distribution system

• Insulation co-ordination of high voltage transmission and transformation equipment

• Degrees of protection provided by enclosure

• Current transformers

• High-voltage ceramic wall bushings technical specification

• High voltage post insulators ceramic material Part 1: Technical Specification

• High voltage test techniques Part 1: General requirements

• Requirements, Terminology and Test Procedure for Neutral Grounding Devices

█ Ordering Information

1. Rated voltage

2. Rated current

3. Resistance value

4. Rated time

5. Inlet and outlet way

6. Cabinet material、color

7. CT parameter

8. Grounding transformer parameter

9. Class of protection

10. Operating environment

11. Other special requirements, etc.


Product detail pictures:

Factory Outlets Chemical Resistance Chart For Aluminum - Neutral Grounding Resistor, NGR EGR – Wepower detail pictures

Factory Outlets Chemical Resistance Chart For Aluminum - Neutral Grounding Resistor, NGR EGR – Wepower detail pictures

Factory Outlets Chemical Resistance Chart For Aluminum - Neutral Grounding Resistor, NGR EGR – Wepower detail pictures

Factory Outlets Chemical Resistance Chart For Aluminum - Neutral Grounding Resistor, NGR EGR – Wepower detail pictures

Factory Outlets Chemical Resistance Chart For Aluminum - Neutral Grounding Resistor, NGR EGR – Wepower detail pictures


Related Product Guide:

Our products are widely recognized and trusted by users and can meet continuously developing economic and social needs for Factory Outlets Chemical Resistance Chart For Aluminum - Neutral Grounding Resistor, NGR EGR – Wepower , The product will supply to all over the world, such as: Honduras, Poland, Ukraine, So far our products have been exported to east Europe, the Middle East, Southeast, Africa and South America etc. We have 13years professional sales and purchase in Isuzu parts at home and abroad and the ownership of the modernized electronic Isuzu parts checking systems. We honor our core principal of Honesty in business, priority in service and will do our best to offer our customers with high quality products and excellent service.
  • This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.
    5 Stars By Prima from Colombia - 2018.08.12 12:27
    The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Adela from Bahrain - 2017.09.28 18:29