2022 New Style Resistivity Of Aluminum On Heating - Load Bank Box and Load Bank Cabinet – Wepower

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Often customer-oriented, and it's our ultimate target to become not only probably the most reputable, trustable and honest provider, but also the partner for our customers for Inverting Amplifier Ground Resistor, Load Bank, Coefficient Of Resistivity Of Aluminum, We are now on the lookout ahead to even larger cooperation with abroad consumers dependant on mutual added benefits. When you are interested in almost any of our products, be sure to experience cost-free to make contact with us for more facts.
2022 New Style Resistivity Of Aluminum On Heating - Load Bank Box and Load Bank Cabinet – Wepower Detail:

The system is a new generation of measurement and control software independently developed by our company for the testing of Marine planet, land and military generator sets and power supply system. It has independent intellectual property rights. The software is flexible and convenient to operate, fully functional, and can be tested independently or in parallel with multiple sets.

Loading and unloading software can be operated in two ways: manual control and automatic control. Manual control can input the load in stages, and can also be used for sudden loading and unloading and display test data on the computer software in real time. Automatic control as long as the input test required by the total power, and loading time, the system will automatically complete 0%, 25%, 50%, 75%, 100%, 100%, 100%, 75%, 50%, 25%, 0% of the test process of loading and unloading, in which the test load power percentage can be arbitrarily set.

Automatic control and manual control can be realized in this interface, in which the load capacity, percentage, load time can be set arbitrarily, there are corresponding instructions in the corresponding position of the load capacity unit, and can display the load test data in real time at the same time.

Series

Type

Capacity

Power factor

Voltage

Dimension

Weight(KG)

Rack mounted Load Bank

TWLB1KW-7KW-R(L)

1KW-7KW

1

DC/AC/50Hz

Customized

6

RL Load Bank

TWLB/AC4OOV-1MVA-RL

R:800KW

L:600KVA

0.8

AC400V/50Hz

6000*2438*2591

6000

TWLB/AC400V-3MVA-RL

R:2400KW

L:1800KVA

7000*2438*2591

15000

TWLB/AC400V-6MVA-RL

R:4800KW

L:3600KVA

9150*2438*2591

25000

RLC Load Bank

TWLB/AC200V-1.5KVA-RLC

R:500KW

L:500KVA

C:500KVA

0.2-1

AC200V/400Hz

6000*2438*2591

5000

Low Voltage Load Bank

TWLB/AC400V-20KW-R

20KW

1

AC400V/50Hz

480*485*680

30

TWLB/AC400V-100KW-R

100KW

700*900*900

80

TWLB/AC400V-200KW-R

200KW

1200*1500*1500

200

TWLB/AC400V-500KW-R

500KW

1500*2000*1800

760

TWLB/AC400V-1MW-R

1000KW

1600*2400*2100

1500

TWLB/AC400V-2MW-R

2000KW

6000*2438*2591

5000

TWLB/AC400V-3MW-R

3000KW

7000

TWLB/AC400V-4KW-R

4000KW

9000

TWLB/AC400V-8MW-R

8000KW

12100*2438*2591

15000

High Voltage Load Bank

TWLB/AC10.5KV-2MW

2000KW

1

AC10.5KV/50Hz

6000*2438*2591

6000

TWLB/AC10.5KV-3MW

3000KW

9150*2438*2591

8000

TWLB/AC10.5KV-5MW

5000KW

12100*2438*2591

10000

TWLB/DC13KV-2MW

2000KW

1

DC12-20KV

12100*2438*2591

35000

█ Selection Notice

When you quote or order, please provide following information in order to fulfill you requirement and service

1.Load Bank voltage type: 1) DC; 2) AC; 3) AC/DC;

2.Load Bank wiring: A Single phase; B three-phase three-wiring system; C three-phase four-wiring system; D others.

3.Load Bank Voltage and frequency;

4.Load bank Power, power fact, capacity (include active power and reactive power);

5.Working and control power supply;

6.Installation place: A Indoor; B Outdoor; C Port; D Offshore;

7.Load Bank sub-tap setting requirements.

8.According to requirement, you can choose following control way

1)Local Panel control;

2)Intelligent control by computer;

3)Remote controller;

9.Way of display, according to requirements.

Friendly Notice: We are willing to provide customers with customized products which typing their logo.


Product detail pictures:

2022 New Style Resistivity Of Aluminum On Heating - Load Bank Box and Load Bank Cabinet – Wepower detail pictures

2022 New Style Resistivity Of Aluminum On Heating - Load Bank Box and Load Bank Cabinet – Wepower detail pictures

2022 New Style Resistivity Of Aluminum On Heating - Load Bank Box and Load Bank Cabinet – Wepower detail pictures

2022 New Style Resistivity Of Aluminum On Heating - Load Bank Box and Load Bank Cabinet – Wepower detail pictures

2022 New Style Resistivity Of Aluminum On Heating - Load Bank Box and Load Bank Cabinet – Wepower detail pictures

2022 New Style Resistivity Of Aluminum On Heating - Load Bank Box and Load Bank Cabinet – Wepower detail pictures

2022 New Style Resistivity Of Aluminum On Heating - Load Bank Box and Load Bank Cabinet – Wepower detail pictures

2022 New Style Resistivity Of Aluminum On Heating - Load Bank Box and Load Bank Cabinet – Wepower detail pictures


Related Product Guide:

"Control the standard by the details, show the toughness by quality". Our firm has strived to establish a highly efficient and stable workers workforce and explored an effective high-quality management system for 2022 New Style Resistivity Of Aluminum On Heating - Load Bank Box and Load Bank Cabinet – Wepower , The product will supply to all over the world, such as: Bulgaria, Porto, Bandung, We strive for excellence, constant improvement and innovation, is committed to make us the "customer trust" and the "first choice of engineering machinery accessories brand" suppliers. Choose us, sharing a win-win situation!
  • We have been looking for a professional and responsible supplier, and now we find it.
    5 Stars By Joanna from Portugal - 2018.06.12 16:22
    The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.
    5 Stars By Julie from Detroit - 2018.12.25 12:43